Technical specifications
Each model group lists its available flow, pressure or vacuum, supply, motor, dimensions and interface parameters.
| Model group | Category | Parameter | Value |
|---|---|---|---|
| OD-03A / OD-03AB / OD-03V / OD-03VB | Performance | Custom flow range | 3–7 L/min |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Performance | Custom pressure range | 2–3 bar |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Performance | Custom vacuum range | -45–-70 kPa |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Electrical | Power | 7–12 W |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Electrical | Voltage | 6 V / 12 V / 24 V |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Electrical | Motor | Brushless motor / brushed motor |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Performance | Service life | Brushless 5000 h / brushed 1000 h |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Performance | Noise | 50–65 dB |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Mechanical | Overall dimensions | 30 × 64 × 49 mm / 30 × 76 × 49 mm |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Mechanical | Weight | 120 g / 140 g |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Electrical | Control options | Optional PWM |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Performance | Pressure configuration | 3 L/min @ 2 bar / 5 L/min @ 2.5 bar / 6 L/min @ 3 bar |
| OD-03A / OD-03AB / OD-03V / OD-03VB | Performance | Vacuum configuration | 3 L/min @ -60 kPa / 5 L/min @ -70 kPa / 6 L/min @ -70 kPa |